Write a review
Average User Review
There is no review for this company
| Selling Offers Language: English Indonesia |
|
| PANEL KUBIKAL / SWITCH GEAR MEDIUM & HIGH VOLTAGE | ||||
|
Switch gear for medium and high voltage used for electric source in industry and any government electric project. it was made for many range (Kilovolt or Ampere).please contact us for further information...........
we will assist you to find what you need....
| ||||
| SEG RELAY MR13-IRSR and SEG RELAY MR13-IE | ||||
|
MRI3 - Digital multifunctional relay for overcurrent protection
2 TD_MRI3_11.07_GB Contents 1 Introduction and application 2 Features and characteristics 3 Design 3.1 Connections 3.1.1 Analog input circuits 3.1.2 Output relays 3.1.3 Blocking input 3.1.4 External reset input 3.2 Relay output contacts 3.2.1 Fault recorder 3.2.2 Parameter settings (see chapter 5) 3.3 LEDs 4 Working....
| ||||
| relay LFZR 111 / LFAA 101 "ALSTHOM" | ||||
|
The LFAA auto-reclose relay provides facilities for
single or two-shot reclosures of one or two circuit breakers following their tripping for a fault on an overhead line. The reclosures can be selected to be either high speed single-phase, or high speed or delayed three-phase. When three-phase reclosure is desired the equipment will convert any single or two-phase LFZR111 Provides....
| ||||
| Relay Sepam 1000+ | ||||
|
Sepam series 20
Suitable for common applications, Sepam series 20 offers simple solutions based on current or voltage metering. b protection of substation incomers and feeders against phase-to-phase and phase-to-earth short-circuits v 16 IDMT tripping curves v adjustable timer hold to detect recurrent faults v switching of groups of settings to adapt to changes in the network....
| ||||
| RELAY MICOM P124 "AREVA" | ||||
|
MiCOM P124 are numerical relays designed to offer
complete overcurrent protection without requiring any external auxiliary supply. They can be applied to a wide variety of high and medium voltage electrical systems as either main or backup protection. Available in a self-powered or in a dual-powered version, they offer three phase and earth fault protection. When supervision functions....
| ||||
| KAVS 100 "ALSTHOM / AREVA" | ||||
|
Functions
Check synchronising The relay checks that the two part of the system are in synchronism by measuring the angle and the slip frequency between the line voltage and the bus voltage. Auto-reclose is blocked if these values exceed the phase angle and slip frequency settings. Manual closure is blocked if these values exceed the system angle and system slip settings. Selectable....
| ||||
| LFAA 101 relay " AREVA" | ||
|
The LFAA auto reclose relay provides facilities for single or two shot reclosures of one or two circuit breakers following their tripping for a fault on an overhead line.
| ||
| RELAY ABB REJ 521 | ||||
|
Earh-Fault Relay REJ 521
Features �Low-set non-directional earth-fault stage with definite-time or inverse definite minimum time (IDMT) characteristic �High-set non-directional earth-fault stage with instantaneous or definite-time characteristic �Circuit-breaker failure protection unit (CBFP) �....
| ||||
| SIEMENS RELAY 7SJ 6 XX | ||||
|
SECTION 26 10 00
MEDIUM-VOLTAGE PROTECTIVE RELAY [MULTIFUNCTION OVERURRENT PROTECTION � 7SJ61/62] PART 1 - GENERAL 1.1 SCOPE A. This section defines medium voltage protective relays for use in multifunction overcurrent protection. 1.2 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1....
| ||||
| SPAJ 140C | ||||
|
OVERCURRENT AND EARTH-FAULT PROTECTION RELAY
OVERCURRENT AND EARTH-FAULT PROTECTION RELAY
| ||||
| MMLG 01 "AREVA & ALSTHOM" | ||||
|
Features
• Test block can be mounted adjacent to Midos modular relays and systems • Test block obviates need to disturb protective system wiring for testing • Monitoring, isolation and secondary injection testing are simplified and quickly performed Types Available • MMLG 01 Standard test block • MMLG 02 Special test block designed for use in busbar protection schemes • MMLG 03....
| ||||
| MVTR 51 RELAY "LASTHOM" | ||||
|
Application and Description
The MVTR 51 multi-shot, three phase auto-reclose relay is designed for use on medium voltage distribution or transmission systems. A block diagram is shown in Figure 2. A typical application is shown in Figure 3. Sequence control and timing functions are performed by a microprocessor. Different operating cycles and timer settings are simply selected by using....
| ||||
| disct conecting switch 20 Kv - 150 Kv | ||
|
150 kV DISCONNECTING SWITCH
Manufacturer : ABB Type : DBRP-170 Designation : Three-column rotary Standard : IEC-129 Frequency : 50 Hz Nominal voltage : 150 kV Highest system voltage : 170 kV Rated continuous current : 2500 A Impulse withstand voltage (BIL) Between phases and between phases and Earth : 750 kV Rated short time current (3 sec.) : 40 kA Type of operating mechanism Main....
| ||
| MCAG RELAY "AREVA"/"ALSTOM" | ||||
|
The MCAG relay, used with a stabilising resistor, is
designed for applications where sensitive settings with stability on heavy through faults are required, and is recommended for balanced and restricted earth fault, bus-zone and certain forms of differential protection for generators, auto-transformers, reactors and motors. The relay operates as a high impedance unit protection scheme.....
| ||||
| MVAX 21 "ALSTOM" | ||||
|
MVAX 12/21/31/91 498
Type MVAX 12/21/31/91: Trip circuit supervision relays Features � Low burden � Trip circuit can be supervised with breaker open or closed � Mis-tripping of breaker by accidental short-circuits avoided � No false alarms given due to protection operation Application The Type MVAX relay....
| ||||
| relay MCGG, 22, 52, 62, 82 "ALSTOM" | ||||
|
Section 1. DESCRIPTION
The MCGG 22, 42, 52, 62 and 82 are single, two, three or four pole overcurrent relays, with separate measuring boards for each phase or earth fault input. The MCGG 53 and 63 are three pole versions, having their phase inputs combined onto one measuring board. Each pole of the relay provides a choice of four IDMT characteristics and three definite time....
| ||||
| MVVA AUXILARY REALAY "AREVA / ALSTOM " | ||||
|
Application
The type MVAA is a low burden auxiliary relay which can be used where a scheme demands several contacts for event recording, alarm initiation, contact logic arrangements, etc The relay can be supplied fitted with normal duty contacts and/or with heavy duty blow-out contacts. Description MVAA relays are voltage operated attracted armature units of compact design with a....
| ||||
| SURGE PROTECTION "DHEN" OBBO" ABB" MG. | ||||
|
""DHEN" RADIO BASE STATION, CELLSITE SURGE PROTECTION
Uc 225 Va, Imp 15/60kA, "DHEN" RADIO BASE STATION, CELLSITE SURGE PROTECTION Uc 225 Va, Imp 15/60kA,
| ||||
| HFA MULTICONTAC AUXILIARY RELAY "GE" | ||||
|
HFA Multicontact Auxiliary Relay
The type HFA relay is designed for applications where a number of auxiliary functions must be performed simultaneously. Six contacts are provided. If more than six circuits are to be controlled, the coils of two or more relays may be connected in series (DC only) or in parallel. ----------------------------------------------------------------- --------....
| ||||
| Sell: Relay AEG PS431 [Aug. 22, 2008 5:44:54] | ||
|
PS431 Time-Overcurrent Protection Device
Functions to be tested: Definite or IDMT overcurrent protection Breker failure protection Measuring circuit monitoring Residual overcurrent protection with DT or IDMT char. Reverse interlocking Event recording Fault recording
| ||